title: Errors
slug: legacy-doc-gk2/errors
icon: 🚨
createdAt: 2024-01-15T00:51:43.384Z
---

Details about the detection and handling of errors on the micro**DRIVE** units.

The micro**DRIVE** units datalog two separate error sectors. The two bitfields and the details of each entry can be found below. The bits are set when the described event occurs.

## Error 1

:::hint{type="info"}
Bit meaning of the Error 1 field logged internally on micro**DRIVE&#x20;**&#x75;nits. Error bit number matches CAN error code.
:::



| **Error Bit** | **Name**                   | **Description**                                                                                                                                                                                                                                         |
| ------------- | -------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| 0             | Internal Error - Firmware  | Internal error - contact us for assistance.                                                                                                                                                                                                             |
| 1             | Internal Error - Firmware  | Internal error - contact us for assistance.                                                                                                                                                                                                             |
| 2             | Configuration Corrupt      | The loaded configuration was corrupted on the unit. Connect to the configuration tool for reset. Unable to internally reset to defaults. The motor drive is disabled.                                                                                   |
| 3             | Configuration Reset        | The loaded configuration was reset to defaults. The configuration was corrupt. Successfully reset to defaults.                                                                                                                                          |
| 4             | Power Supply Fault 1       | An onboard power supply for the logic circuit faulted. Likely a hardware issue. Contact us for further details.                                                                                                                                         |
| 5             | Power Supply Fault 2       | An onboard power supply for the logic circuit faulted. Likely a hardware issue. Contact us for further details.                                                                                                                                         |
| 6             | Bridge Test Fault          | The bridge test returned a negative result, indicating hardware or motor damage. Inspect or replace the unit.                                                                                                                                           |
| 7             | Over Voltage Fault         | The bus voltage exceeded the unit maximum. The motor drive was shut down and will resume once the event clears.                                                                                                                                         |
| 8             | Under Voltage Fault        | The bus voltage dropped below the unit minimum. The motor drive was shut down and will resume once the event clears.                                                                                                                                    |
| 9             | Over Config Voltage Fault  | The bus voltage exceeded the configured maximum. The motor drive was shut down and will resume once the event clears.                                                                                                                                   |
| 10            | Under Config Voltage Fault | The bus voltage dropped below the configured minimum. The motor drive was shut down and will resume once the event clears.                                                                                                                              |
| 11            | Absolute Over Temp Fault   | The unit reached its absolute maximum over temperature limit (135 degrees C), and the motor drive was temporarily disabled. The event will clear after the temperature drops.                                                                           |
| 12            | Internal Error - Hardware  | Internal error - contact us for assistance.                                                                                                                                                                                                             |
| 13            | Internal Error - Hardware  | Internal error - contact us for assistance.                                                                                                                                                                                                             |
| 14            | Signal Input Lost          | The loss of a valid signal input configured period will stop the motor drive output. The drive will resume when the signal is returned, and the throttle is 0%. The throttle 0% setpoint requirement can be overwritten when using CAN Bus signalling.  |
| 15            | Internal Error - Hardware  | Internal error - contact us for assistance.                                                                                                                                                                                                             |
| 16            | Bootloader Reported Fault  | The bootloader reported a fault with either firmware or recovery sections. Likely an update has failed or a hardware fault has occurred.                                                                                                                |

## Error 2

:::hint{type="info"}
Currently unused, reserved for future use.
:::