Logging Settings
The logging settings adjust the behaviour of the onboard logging available on microDRIVE units.
Description | If this option is active logs will be cleared on first boot after changing the logging frequency. This ensures that all logs on the ESC were recorded with the same frequency. |
---|---|
CAN Name | LOG_CLR_HZ_CHG |
Units | N/A |
Advanced | YES |
Description | Controls the event that triggers data logging or disables the logging entirely. |
---|---|
CAN Name | LOG_TYPE |
Units | N/A |
Advanced | NO |
Value Mappings:
- 0 -> Always On
- 1 -> When Motor Running
- 2 -> Disabled
Description | The rate at which the ESC will log data to the onboard memory. Logging is cyclical, and will overwrite the oldest data. |
---|---|
CAN Name | LOG_FREQ |
Units | N/A |
Advanced | NO |
Value Mappings:
- 0 -> 1Hz (~3 days, 8 hours)
- 1 -> 10Hz (~8 hours)
- 2 -> 20Hz (~4 hours)
- 3 -> 50Hz (~1 hour, 30min)
- 4 -> 100Hz (~45 min)
Description | This option toggles the logging of 'MCU Temperature' on or off. |
---|---|
CAN Name | LOG_MCU_TEMP |
Units | N/A |
Advanced | YES |
Description | This option toggles the logging of 'Motor Temperature' on or off. |
---|---|
CAN Name | LOG_MOT_TEMP |
Units | N/A |
Advanced | YES |
Description | This option toggles the logging of 'Phase Current' on or off. |
---|---|
CAN Name | LOG_PHASE_CURR |
Units | N/A |
Advanced | YES |
Description | This option toggles the logging of 'Power' on or off. |
---|---|
CAN Name | LOG_POWER |
Units | N/A |
Advanced | YES |
Description | This option toggles the logging of 'Voltage Ripple' on or off. |
---|---|
CAN Name | LOG_RIPPLE |
Units | N/A |
Advanced | YES |