microDRIVE LP
Integration
Mounting and Cooling
for the enclosed micro drive lp, four mounting holes (m2 or #2 56 suitable) are provided to attach the unit to your application securely it is crucial to use the appropriate tightening torque suitable for the fastener and the type of mounting material being used while the micro drive lp is primarily intended for aerial vehicles, it is worth noting that implementing vibration isolation for the unit, especially in land based applications, will significantly enhance its durability over time it is essential to incorporate adequate mechanical strain relief for all cables connected to the unit this ensures appropriate support and protection against any undue stress or tension on the wires cooling considerations the micro drive lp is supplied with a built in housing that effectively meets the thermal management needs of the device to fully utilise the 60a phase current rating in this setup, it is necessary to ensure a minimum airflow of 6 m/s \[20 ft/s] parallel to the heatsink (for a 25°c \[77°f] ambient air temperature)