microFLUX 4LP
Settings
Channel 3 Settings
channel 3 command message response description determines under what conditions the channel will respond to channel command messages command messages allow the channel to be toggled on or off during operation id 0x01cb dronecan name ch3 cmd msg rsp units n/a advanced no value mappings 0 > no response 1 > on commands only if armed 2 > always respond channel 3 id description the battery/circuit/device/hardpoint id of channel 3 this setting determines the id used in telemetry dronecan messages for this channel, and to which hardpoint command messages it responds to id 0x0135 dronecan name ch3 id units n/a advanced no channel 3 is priority description set this channel as a priority channel some error responses can be configured to not turn priority channels off channels that are critical to vehicle operation, such as a flight controller, should have this enabled id 0x01a9 dronecan name ch3 is priority units n/a advanced no channel 3 overcurrent limit description the output current at which the channel overcurrent error and response is triggered a warning will be set before the limit is reached, the warning will be displayed in telemetry id 0x012d dronecan name ch3 ov cur lim units units are in amps (a) advanced yes channel 3 overcurrent response description the response behavior to the channel overcurrent limit being exceeded id 0x0131 dronecan name ch3 ov cur rsp units n/a advanced no value mappings 0 > no action 1 > turn channel off channel 3 overtemperature limit description the temperature at which the channel overtemperature error and response is triggered a warning will be set before the limit is reached, the warning will be displayed in telemetry id 0x0119 dronecan name ch3 ov t lim units units are in degrees celsius (°c) advanced yes channel 3 overtemperature response description the response behavior to the channel overtemperature limit being exceeded id 0x011d dronecan name ch3 ov t rsp units n/a advanced no value mappings 0 > no action 1 > turn channel off channel 3 overvoltage deviation limit description sets the percentage deviation of the output voltage above the configured voltage level that triggers the channel overvoltage error and response a warning will be set before the limit is reached, the warning will be displayed in telemetry id 0x0109 dronecan name ch3 ov v lim units units are in % deviation (%) advanced yes channel 3 overvoltage deviation response description the response behavior to the channel overvoltage deviation limit being exceeded id 0x0111 dronecan name ch3 ov v lim rsp units n/a advanced no value mappings 0 > no action 1 > turn channel off channel 3 power off upon disarming description when enabled, the channel will automatically turn off upon the transition from armed to disarmed id 0x01ad dronecan name ch3 pwr off dsrm units n/a advanced no channel 3 power on at startup description turns channel 3 on with the configured settings on device startup id 0x00f6 dronecan name ch3 on startup units n/a advanced no channel 3 power on upon arming description when enabled, the channel will automatically turn on upon the transition from disarmed to armed id 0x01b1 dronecan name ch3 pwr on arm units n/a advanced no channel 3 undercurrent warning description sets the output current that triggers the channel undercurrent warning when active, the warning will show in telemetry and cause the channel led to change to a warning state id 0x0129 dronecan name ch3 un cur warn units units are in amps (a) advanced yes channel 3 undervoltage deviation limit description sets the percentage deviation of the output voltage below the configured voltage level that triggers the channel undervoltage error and response a warning will be set before the limit is reached the warning will be displayed in telemetry id 0x010d dronecan name ch3 un v lim units units are in % deviation (%) advanced yes channel 3 undervoltage deviation response description the response behavior to the channel undervoltage deviation limit being exceeded id 0x0115 dronecan name ch3 un v lim rsp units n/a advanced no value mappings 0 > no action 1 > turn channel off channel 3 voltage level description sets the discrete voltage level of channel 3 id 0x00fa dronecan name ch3 v lvl units n/a advanced no value mappings (lv channel) 0 > 3 3v 1 > 5 0v 2 > 5 4v 3 > 7 2v 4 > 8 2v 5 > 10v 6 > 10 3v 7 > 12v value mappings (hv channel) 0 > 12v 1 > 15v 2 > 16v 3 > 19v 4 > 21 3v 5 > 24v 6 > 25 2v 7 > 28v