datalogging control description controls the event that triggers data logging or disables the logging entirely id 0x0153 dronecan name log ctrl units n/a advanced no value mappings 0 > always on 1 > when at least one channel is on 2 > disabled datalogging frequency description the rate at which the device will log data to the onboard memory logging is cyclical, and will overwrite the oldest data id 0x0152 dronecan name log freq units n/a advanced no value mappings 0 > 1hz 1 > 10hz 2 > 20hz 3 > 50hz 4 > 100hz